GLAVALUniversal
NHTSA vehicle recall lookup

2009 Glaval Universal recalls

There are 11 NHTSA recall campaigns associated with this vehicle configuration.

Explore full safety analysis
Live NHTSA dataVehicle taxonomy resolved as Glaval Universal.
NHTSA recall campaigns11
NHTSA consumer complaints0
Primary sourceNHTSA
Most-mentioned components
EQUIPMENT ADAPTIVE/MOBILITY · 5EQUIPMENT:APPLIANCE:AIR CONDITIONER · 3ELECTRICAL SYSTEM · 1EQUIPMENT · 1INTERIOR LIGHTING · 1
Campaign 14V226000

Equipment Adaptive/Mobility

Jun 4, 2016
Summary

Glaval Bus (Glaval) is recalling certain model year 2007-2012 Universal, Primetime, Sport, Concorde, Titan, Titan II, Entourage and Apollo transit buses manufactured January 1, 2007, through December 3, 2012, and equipped with certain Ricon S-series and K-series wheelchair lifts, with an optional armored pendant cable. The armored cable may be positioned such that it does not clear the wheelchair lift.

Risk

If the cable does not clear the wheel chair lift it may contact the power lug and if it does not have a nonconductive cover, or it has an improperly installed non-conductive cover, then a short circuit may occur that could result in a fire.

Remedy

Glaval will notify owners, and Ricon will send owners a supplemental cover kit and instructions, free of charge. The recall is expected to begin in June 2014. Owners may contact Glaval customer service at 1-800-445-2824 or Ricon Customer Service at 1-800-322-2884 or by e-mail at recall.admin@wabtec.com.

Open campaign page →
Campaign 14V599000

Equipment Adaptive/Mobility

Feb 9, 2016
Summary

Forest River, Inc. (Forest River) is recalling certain model year 2006-2014 Glaval Universal, Primetime, Sport, Titan, and Titan II transit and shuttle buses manufactured January 1, 2006, to September 26, 2014, and equipped with certain model S2005, S2010, S5005, S5010, S5505, and S5510 wheelchair lifts manufactured by Ricon. The platform side plate of the affected wheelchair lifts may crack.

Risk

If the platform side plates crack, the lift platform can separate from the lift and come to rest against the vehicle's lift door. When the doors are opened, the platform may fall out, increasing the risk of injury to the lift operator.

Remedy

Forest River will notify owners to take buses to a Ricon dealer or service center who will install supplemental platform support bumpers. Any platform that has already started cracking will be replaced, free of charge. The recall began on December 1, 2014. Owners may contact Glaval customer service at 1-800-445-2825 or Ricon customer service at 1-800-322-2884.

Open campaign page →
Campaign 12V011000

Equipment › Appliance › Air Conditioner

Jan 1, 2013
Summary

GLAVAL IS RECALLING CERTAIN MODEL YEAR 2006 THROUGH 2007 TRANSIT BUSES BUILT ON FORD, GMC, CHEVROLET, AND FREIGHTLINER CHASSIS AND EQUIPPED WITH CARRIER GENV EM-1 EVAPORATOR UNITS. DUE TO TIME, TEMPERATURE, AND/OR VIBRATION, THE FUSE MAY LOOSEN IN THE FUSE HOLDER RESULTING IN HIGH RESISTANCE AND ARCING.

Risk

IF SUFFICIENT ARCING OCCURS, THE FUSE HOLDER MAY MELT, AND A VEHICLE FIRE MAY OCCUR.

Remedy

GLAVAL WILL NOTIFY OWNERS AND PROVIDE INFORMATION ON HOW TO OBTAIN THE RETROFIT KIT FROM CARRIER ALONG WITH REPAIR INSTRUCTIONS. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON JANUARY 14, 2012. (SEE CARRIER'S RECALL CAMPAIGN 11E-003.) OWNERS MAY CONTACT CARRIER AT 1-800-348-7440.

Open campaign page →
Campaign 13V520000

Electrical System

Jun 10, 2014
Summary

Glaval Bus is recalling certain model year 2009-2010 Entourage, Sport, Universal, Titan, Titan II, Apollo, Primetime, Concorde, and Concorde II transit buses manufactured August 4, 2009, through June 7, 2010 and equipped with A&M Systems-brand electric door actuators. Voltage spikes may damage electrical components and electrical circuits within the actuator, causing the circuit board to develop high resistance.

Risk

High resistance may cause the circuit board to overheat, increasing the risk of a fire.

Remedy

Glaval Bus will notify owners and dealers will replace the circuit board, free of charge. The recall began on November 14, 2013. Owners may contact Glaval Bus at 1-574-262-2212.

Open campaign page →
Campaign 12V580000

Equipment

Oct 12, 2012
Summary

Glaval Bus is recalling certain model year 2007-2012 transit buses, models: Entourage, Sport, Universal, Titan, Titan II, Apollo, Primetime, and Concord; and manufactured January 1, 2007, through December 3, 2012. The buses are equipped with a Ricon manufactured wheelchair lift which has an optional armored pendant cable. The cable may have been installed such that it doesn't clear the wheelchair lift and without a protective cover, or a misinstalled protective cover.

Risk

The cable may contact the power lug at the base of the wheel chair lift causing a short circuit that could result in a fire.

Remedy

Glaval Bus will notify owners and direct them to contact Ricon. Ricon will provide a supplemental cover kit and instructions, free of charge. The recall campaign began on January 23, 2013. Owners may contact Glaval Bus at 1-574-262-2212 or Ricon at 1-818-267-3000.

Open campaign page →
Campaign 12V321000

Equipment Adaptive/Mobility

Sep 7, 2012
Summary

GLAVAL IS RECALLING CERTAIN BUSES EQUIPPED WITH BRAUN CENTURY-2 AND/OR VISTA-2 WHEELCHAIR LIFTS. OVER TIME AND WITH FREQUENT USE, THE ROLL STOP LATCHES ON THE OUTER BARRIER MAY BECOME BENT OR MISALIGNED.

Risk

A WHEELCHAIR OCCUPANT MAY DEFEAT OR RIDE OVER THE INSUFFICIENTLY LATCHED ROLL STOP. IF THIS OCCURS WHEN THE LIFT PLATFORM IS IN AN ELEVATED POSITION, THE WHEELCHAIR’S OCCUPANT COULD FALL AND SUSTAIN INJURY.

Remedy

GLAVAL WILL NOTIFY OWNERS, AND THE REPAIRS WILL BE PERFORMED BY AUTHORIZED BRAUN DEALERS FREE OF CHARGE. OWNERS MAY CONTACT GLAVAL BUS AT 1-800-347-7440.

Open campaign page →
Campaign 09V402000

Equipment › Appliance › Air Conditioner

Mar 10, 2010
Summary

GLAVAL BUS IS RECALLING CERTAIN MODEL YEAR 2008 AND 2009 TRANSIT BUSES EQUIPPED WITH CARRIER K410 ROOFTOP CONDENSERS. INADEQUATE OVERCURRENT PROTECTION OF ONE OR MORE OF THE FANS IN THE K410 CONDENSER MAY CAUSE OVERHEATING OF THE FAN'S WIRES.

Risk

OVERHEATING OF THE CONDENSER UNIT WIRES COULD RESULT IN A FIRE CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

Remedy

GLAVAL BUS WILL NOTIFY OWNERS TO CONTACT AN AUTHORIZED CARRIER DEALER TO OBTAIN THE REMEDY. PLEASE ALSO SEE CARRIER'S DEFECT REPORT 09E-055. THE SAFETY RECALL BEGAN ON OCTOBER 28, 2009. OWNERS MAY CONTACT CARRIER AT 1-800-673-2431 OR GLAVAL BUS TOLL-FREE AT 1-800-450-2211.

Open campaign page →
Campaign 10V143000

Equipment Adaptive/Mobility

Dec 4, 2010
Summary

GLAVAL BUS IS RECALLING CERTAIN MODEL YEAR 2006 THROUGH 2010 UNIVERSAL, TITAN, TITAN II, PRIMETIME, SPORT, AND APOLLO TRANSIT BUSES MANUFACTURED BETWEEN DECEMBER 2007 AND DECEMBER 2009 FITTED WITH RICON PUBLIC USE LIFTS. THE RESTRAINT BELT ON THESE LIFTS WAS DESIGNED TO PREVENT THE LIFT FROM MOVING, UNLESS THE TONGUE OF THE BELT IS FULLY ENGAGED AND LATCHED IN THE BUCKLE. RICON HAS DISCOVERED, HOWEVER, THAT IT IS POSSIBLE FOR THE OPERATOR TO INSERT THE BELT TONGUE INTO THE BUCKLE WITHOUT FULLY ENGAGING THE LATCHING MECHANISM. IN THIS CASE, THE RESTRAINT BELT WOULD APPEAR TO BE LATCHED, AND THE OPERATOR COULD RUN THE LIFT. IF THE RESTRAINT BELT TONGUE IS NOT FULLY ENGAGED INTO THE RESTRAINT BELT BUCKLE, AND LATCHED, THE LIFT MAY OPERATE WITH AN OCCUPANT ON THE PLATFORM.

Risk

THE USER OF THE LIFT COULD BE INJURED SHOULD THE LIFT MOVE WITHOUT THE RESTRAINT BELT PROPERLY BUCKLED.

Remedy

GLAVAL BUS IS WORKING WITH RICON AND RICON WILL BE PERFORMING THE REMEDY FOR THIS CAMPAIGN. PLEASE SEE RICON'S DEFECT REPORT 09E-060. RICON WILL PROVIDE CUSTOMERS WITH A WARNING DECAL AND A DVD-BASED TRAINING AID. THE SAFETY RECALL BEGAN ON APRIL 26, 2010. OWNERS MAY CONTACT RICON AT 1-818-267-3000 OR GLAVAL BUS AT 1-800-322-2884.

Open campaign page →
Campaign 09V421000

Interior Lighting

Apr 10, 2011
Summary

GLAVAL BUS IS RECALLING CERTAIN MODEL YEAR 2001 THROUGH 2009 TRANSIT BUSES EQUIPPED WITH LUMINATOR HORIZON LED SIDE DESTINATION SIGNS. THE CONNECTOR BOARD CAN CORRODE DUE TO AN ACCUMULATION OF MOISTURE UNDER THE CONNECTOR.

Risk

A SHORT COULD OCCUR, POSSIBLY CAUSING SMOKE AND FIRE.

Remedy

GLAVAL BUS WILL NOTIFY OWNERS AND LUMINATOR WILL REPAIR THE BUSES FREE OF CHARGE. PLEASE SEE LUMINATOR'S DEFECT REPORT 09E-054. THE SAFETY RECALL BEGAN ON NOVEMBER 10, 2009. OWNERS MAY CONTACT LUMINATOR AT 1-972-516-3033 OR GLAVAL BUS AT 1-574-262-2212.

Open campaign page →
Campaign 10V144000

Equipment Adaptive/Mobility

Dec 4, 2010
Summary

GLAVAL BUS IS RECALLING CERTAIN MODEL YEAR 2007 THROUGH 2010 TRANSIT BUSES MANUFACTURED BETWEEN OCTOBER 2007 THROUGH DECEMBER 2009, EQUIPPED WITH CERTAIN RICON S SERIES AND K SERIES L-MODEL WHEELCHAIR LIFTS. DUE TO A PROBLEM IN THE SOFTWARE THAT CONTROLS THE LIFT'S "UP" FUNCTION, SHOULD THE "UP" SWITCH BE RELEASED BEFORE THE FLOOR LEVEL LIMIT SWITCH IS ACTIVATED, THE LIFT MAY CONTINUE ITS UPWARD TRAVEL AND MAY OVERRUN THE FLOOR LEVEL CUT OFF POINT.

Risk

WHEN THE PLATFORM OVERRUNS THE VEHICLE FLOOR LEVEL AND STOPS AT AN ANGLE FROM 15-20 DEGREES, IT IS POSSIBLE FOR A PERSON IN A WHEELCHAIR TO TIP OVER AND FOR SOMEONE STANDING ON THE PLATFORM TO FALL, POSSIBLY RESULTING IN INJURIES.

Remedy

GLAVAL BUS WILL NOTIFY OWNERS AND THE REPAIRS WILL BE PERFORMED BY AUTHORIZED RICON DEALERS FREE OF CHARGE. A SOFTWARE SOLUTION FOR THIS SAFETY DEFECT IS UNDER INVESTIGATION. UNTIL THE SOFTWARE SOLUTION IS AVAILABLE, RICON WILL PROVIDE OWNERS WITH A BULLETIN OUTLINING PROPER WHEELCHAIR LIFT OPERATION AND WILL SHIP OWNERS A DVD-BASED TRAINING AID TO PROMOTE PROPER LIFT OPERATION AT NO COST. THE SAFETY RECALL BEGAN ON APRIL 26, 2010. OWNERS MAY CONTACT RICON AT 1-818-267-3000 OR GLAVAL BUS AT 1-800-322-2884.

Open campaign page →
Campaign 09V212000

Equipment › Appliance › Air Conditioner

Sep 6, 2009
Summary

GLAVAL BUS IS RECALLING 45 MODEL YEAR 2008 AND 2009 TRANSIT BUSES MANUFACTURED BETWEEN JULY 1, 2008 AND JANUARY 31, 2009, EQUIPPED WITH CARRIER K410 ROOFTOP MOUNTED CONDENSERS. THE COVER OF THE CONDENSER ASSEMBLY MAY INTERFERE WITH THE COIL HEADER WHEN THE COVER IS PLACED ON THE UNIT ASSEMBLY. THE POTENTIAL INTERFERENCE PREVENTS THE COVER FROM RESTING ON THE UNIT MOUNTING SURFACE, CREATING A GAP BETWEEN THE COVER AND UNIT ASSEMBLY.

Risk

THIS CONDITION WILL NOT PERMIT THE COVER FASTENERS TO SECURELY CLAMP THE COVER TO THE UNIT ASSEMBLY, WHICH MAY RESULT IN THE COVER DISLOCATING FROM THE UNIT DURING OPERATION, POSSIBLY CAUSING A CRASH OR CAUSE INJURY TO PEDESTRIANS.

Remedy

GLAVAL WILL NOTIFY OWNERS AND REPAIR THE BUSES FREE OF CHARGE. THE SAFETY RECALL BEGAN ON JULY 14, 2009. OWNERS MAY CONTACT GLAVAL AT 1-800-333-0510 OR CARRIER AT 1-800-673-2431.

Open campaign page →

Does this mean my vehicle has an open recall?

No. Year/make/model results show campaigns associated with this vehicle configuration. RecallSight can decode your VIN and build the research dossier here; NHTSA remains authoritative for whether a specific VIN has an unrepaired recall.

Check a VIN on RecallSight →

What should I do?

Review the remedy and manufacturer guidance for each campaign. Safety recall remedies are generally provided by manufacturers without charge when the vehicle is covered.

Model history

See every Glaval Universal model year

Browse all official vPIC model years, including years RecallSight has not indexed yet, then compare the evidence as each year is loaded.

Open Glaval Universal model history →
Continue